...Testing Cam and Crank Sensors Using an Oscilloscope In this video Phil Rutt of Pico Technology gives a demonstration on completing a dual test comprising of both camshaft and crankshaft sensors, using Pico back-pinning probes (TA008), and battery clip (TA158). Phil covers connection to th...
...In this video Phil Rutt of Pico Technology gives a demonstration on completing an injector test using Pico 20/60 A current clamp (TA018), Pico breakout lead (TA012), a Pico 10:1 attentuator (TA197), and Pico's Blue premium test lead (TA125). Phil covers connection to the vehicle and the Pi...
...In this video Phil Rutt of Pico Technology gives a demonstration on completing an Oxygen sensor test using Pico's Blue premium test lead (TA125), and back-pinning probes (TA008). Phil covers connection to the vehicle, the PicoScope settings required, and discusses the waveform result seen...
...In this video Phil Rutt of Pico Technology gives a demonstration on completing a Secondary ignition test using Pico's Secondary ignition pick-up (MI074) and 4 HT Extension leads (TA037). Phil covers connection to the vehicle, the PicoScope settings required, and discusses the waveform resu...
...In this video Phil Rutt of Pico Technology gives a demonstration on completing a Secondary ignition test using Pico's 2000 A clamp (TA167). Phil covers connection to the vehicle, the Current Clamp and PicoScope settings required, and discusses the waveform result seen onscreen. Phil also i...
...Steve Smith is presenting this video guide for filtering with PicoScope.This video relates to the article "Filtering When, Where, Why and How?" at: https://www.picoauto.com/library/trai.... This is a great source to understanding how filters work and how to set them up....
...Cranking Current Testing Using an Oscilloscope Frank Massey's Top Ten tests with PicoScope: #1 Cranking current In our first video, Frank discusses using PicoScope to observe voltage drop against load, measured as current by the consumer. Frank discusses theory of testing, what is be...
...Frank Massey's Top Ten tests with PicoScope: #2 Actuator Duty Current In this, Frank's second test he looks at a Turbo Control actuator, measuring control duty and current. Frank discusses the theory of the test, what is being tested and the simplicity of using a scope and current cl...
...Frank Massey's Top Ten Tests with PicoScope: #3 Air mass meter conversion digital to analogue In Frank's third test, he looks at a converting a digital air mass value to an analogue value. Frank discusses the theory of the test, what is being tested and the simplicity of using a sco...
...Frank Massey's Top Ten Tests with PicoScope: #4 Wide band lambda Frank discusses the theory of the test, what is being tested and the simplicity of using a scope for this test. He covers timebases, current and voltage ranges, and of course the physical connections required. Objectiv...