...Audi A6 (4B) Fuse no. 14 burnt, central locking, window lift, seat heater, reading, footwell and interior lamps, anti-theft warning system, sliding roof, anti-theft warning system sporadically no function. If there are complaints with these vehicles about the faults specified above, then...

...Audi A6 (4B) All models with parking aid Warning buzzer does not work. If there are complaints with these vehicles that the warning buzzer for the parking aid does not work, one possible cause is a faulty control unit. The entry "Warning buzzer – short-circuit to plus" is stored in th...

...Audi A6, all models model years 1997 – 2004 Engine doesn't start If this fault is complained about, then a damaged wire harness of the immobilizer may be the cause. Also the error “Signal from receiver coil or key too weak“ may be stored. The wire harness may have been installed...

...Audi A6 Model year from 1998 to 02.2002 Battery charge control lamp illuminates If there are complaints about the above-mentioned fault, the cause could be a defective voltage regulator. In the case of the A6, regulators made by Bosch and Valeo fitted. In this case, however, only...

...Audi A6 build year up to 1997 A4 build year up to 2001 Non-functioning automatic opening and closing of the power windows after disconnecting the battery. After disconnecting the battery, the automatic opening and closing is functionless. The automatic must be re-initialised aft...

...Audi A6 (4B...) All models without xenon headlights Fault lamp for headlight range adjustment illuminates. The fault lamp for headlight range adjustment is fitted as standard in all instrument clusters of this vehicle model. However, it is connected only in the case of vehicles wit...

...Audi A6, 2.4 l Model year 1998 Car cuts out If there are complaints about the above-mentioned fault, the cause could be a chafed cable. Chafing of the insulation occurs in the case of the yellow positive cable for the fuel pump located in the fuel tank. Through subsequent contact w...

...Audi A6 (4F) Model year: 2005 – 2008 Engine: V6-TDI + 4.2-FSI Cooling fan run-on / discharged battery With the above-mentioned batteries, faulty run-on of the cooling fan can lead to the battery discharging. The vehicle manufacturer has taken heed of the problem already and and a ...

...Audi A6 (4B..) All models “Door open” displayed in the instrument cluster, interior lighting not working, anti-theft alarm triggered erroneously. If there are complaints with these vehicles that an open door is indicated in the instrument cluster when the doors are closed, that the...

...Audi A6 (4B, C5) Petrol engine: 4-cylinder 2.0 litre 6 + 8-cylinder Engine overheats/ Radiator fan without function With the above-mentioned vehicles, a blown fuse can lead to the engine overheating. A 40 A fuse is insufficient for the radiator fan and can blow du...